ANALISA KEANDALAN SISTEM CATU DAYA GEDUNG TOWER

Authors

  • Afan Setiawan Program Studi Diploma IV Teknik Listrik Bandara Politeknik Penerbangan Indonesia Curug Author

DOI:

https://doi.org/10.71282/jurmie.v3i11.2705

Keywords:

99.999% Availability; CASR 171; Power supply system reliability; Tier IV topology; Tower building.

Abstract

The reliability of the tower building power supply system is a crucial factor in ensuring the safety and continuity of air navigation services, particularly communication facilities that are required to achieve a minimum availability level of 99.999% in accordance with CASR 171. The main problem addressed in this study is how to maintain this level of availability and identify the factors affecting the reliability of the tower building electrical power supply system. This study aims to analyze the existing power supply system configuration, identify potential points of failure, and evaluate its compliance with national and international standards. The research methodology includes documentation studies, field observations, and technical analysis of both the main and backup power supply systems in several tower buildings, with the JATSC tower serving as the case study. The results indicate that achieving 99.999% availability can only be supported through the implementation of a layered and redundant power supply system with a fault-tolerant Tier IV topology. The conclusions emphasize the importance of national standardization of tower building power supply system configurations. It is recommended that the implementation of Tier IV topology be carried out gradually across all tower buildings in Indonesia to enhance reliability, safety, and operational efficiency in aviation services.

Downloads

Download data is not yet available.

References

Abadi, M. F., Bordbari, M. J., Haghighat, F., & Nasiri, F. (2025). Dynamic maintenance cost optimization in data centers: An availability-based approach for K-out-of-N systems. Buildings, 15(7), 1057. https://doi.org/10.3390/buildings15071057

Azizi, A., Morovati, S., Zamani, A., Piruzza, J., Guo, D., Liu, Z., & Taimela, P. (2026). Strengthening data center operations using grid-forming battery energy storage as a line-interactive uninterruptible power supply. International Journal of Electrical Power & Energy Systems, 175, 111638. https://doi.org/10.1016/j.ijepes.2026.111638

Deviatkina, S., & Yaremich, T. (2024). Mathematical reliability model of the aerodrome power supply system. Electronics and Control Systems, 4(82), 41–47. https://doi.org/10.18372/1990-5548.82.19380

Frederick, L., & Pai, M. M. M. (2025). Generation of real world maintenance data of data center uninterruptible power supply systems and failure prediction. IEEE Access, 13, 155096–155109. https://doi.org/10.1109/ACCESS.2025.3605758

Ghosh, S., & Damodara, J. (2026). Scalable data centers – Power generation and delivery challenges and solutions. Energy Reports. https://doi.org/10.1016/j.egyr.2026.109178

Huang, L.-L., Wang, Z.-W., Xu, H.-R., Wang, B.-L., & Chen, W.-W. (2025). FMEA-based risk mitigation for hospital UPS failures. Results in Engineering, 27, 106833. https://doi.org/10.1016/j.rineng.2025.106833

Institute of Electrical and Electronics Engineers. (1996). IEEE recommended practice for emergency and standby power systems for industrial and commercial applications. IEEE.

Institute of Electrical and Electronics Engineers. (2007). IEEE recommended practice for the design of reliable industrial and commercial power systems (IEEE Std 493-2007). IEEE.

International Civil Aviation Organization. (2001). Aeronautical telecommunications: Annex 10 to the Convention on International Civil Aviation, Volume II: Communication procedures including those with PANS status. ICAO. https://www.icao.int/

International Civil Aviation Organization. (2017). Aerodrome design manual: Part 5—Electrical systems (Doc 9157) (2nd ed.). ICAO.

International Civil Aviation Organization. (2018). Annex 14 to the Convention on International Civil Aviation: Aerodromes, Volume I—Aerodrome design and operations. ICAO.

International Electrotechnical Commission. (2017). Uninterruptible power systems (UPS)—Part 1: Safety requirements (IEC 62040-1:2017). IEC.

International Electrotechnical Commission. (2021). Uninterruptible power systems (UPS)—Part 3: Method of specifying the performance and test requirements (IEC 62040-3:2021). IEC.

Katuwu, B. P. P., Manjang, S., & Dewiani. (2026). FMEA-based reliability analysis of airfield lighting electrical systems. In Proceedings of the 2026 5th International Conference on Electronics Representation and Algorithm (pp. 656–660). IEEE. https://doi.org/10.1109/ICERA72709.2026.11666693

Lauzon, J.-W., Kocar, I., & Lesage-Landry, A. (2025). Reliability assessment of distribution systems with microgrids using discrete-time Markov chains. IEEE Transactions on Power Delivery. https://doi.org/10.1109/TPWRD.2025.3647278

Liu, Z. (2025). Current status analysis and improvement suggestions on power supply reliability technologies for airport microgrids. Theory and Practice of Science and Technology, 6(3), 30–33. https://doi.org/10.47297/taposatWSP2633-456905.20250603

National Fire Protection Association. (2022). NFPA 110: Standard for emergency and standby power systems. NFPA.

Riva, R., & Paolini, M. (2025). Data center power supply availability study through dynamic reliability block diagrams – Lessons learned. In 2025 9th International Conference on System Reliability and Safety (pp. 27–33). IEEE. https://doi.org/10.1109/ICSRS68021.2025.11422198

Saleheen, M. Z., Wagner, M., & Wang, H. (2026). Ensuring reliability in 100% renewable microgrids: A scenario-based joint planning and operational design framework. Energy Conversion and Management, 363, 121645. https://doi.org/10.1016/j.enconman.2026.121645

Saleheen, M. Z., Wagner, M., Razzaghi, R., & Wang, H. (2026). Reliability as a design principle: A systematic review and integrated framework for renewable-based microgrids. Energy Conversion and Management: X, 30, 101878. https://doi.org/10.1016/j.ecmx.2026.101878

Shih, T.-H., Chen, C.-T., & Lin, Y.-K. (2026). Critical infrastructure identification in microgrid system via reliability evaluation. https://doi.org/10.1142/S021853932650018X

Sirotskiy, M., & Pugachev, A. (2026). Comparison of uninterruptible power supply reliability in various redundancy systems. Automation and Modeling in Design and Management, 2026(1), 94–100. https://doi.org/10.30987/2658-6436-2026-1-94-100

Telecommunications Industry Association. (2017). Telecommunications infrastructure standard for data centers (TIA-942-B). TIA. http://www.tiaonline.org/standards/catalog/

Uptime Institute. (n.d.). Tier standard: Topology. Uptime Institute.

Wang, Y., Wang, F., Li, S., & Zhang, Y. (2024). Precise modeling and analysis of aviation power system reliability via the aviation power system reliability probability network model. Aerospace, 11(7), 530. https://doi.org/10.3390/aerospace11070530

Yu, Y., Shan, K., Li, H., & Wang, S. (2026). Quantitative impacts of energy system flexibility provision and design/operation on data center reliability and the key influential parameters. Applied Energy, 415, 127904. https://doi.org/10.1016/j.apenergy.2026.127904

Yu, Y., Shan, K., Tang, H., & Wang, S. (2025). Reliability and economic impacts of utilizing battery energy storage in data centers for energy flexibility services in smart grids. Energy Conversion and Management, 339, 119951. https://doi.org/10.1016/j.enconman.2025.119951

Zhang, S., Gao, J., Qian, H., Yu, J., Luo, S., & Guo, Q. (2024). Power system operational reliability assessment based on the data center energy consumption elastic space. Frontiers in Energy Research, 12, 1370861. https://doi.org/10.3389/fenrg.2024.1370861

Zhang, S., Liu, W., Wan, H., Wang, T., Cheng, R., & Li, H. (2024). Comprehensive reliability assessment method for distribution networks considering IIDG low voltage ride-through control. International Journal of Electrical Power & Energy Systems, 159, 110034. https://doi.org/10.1016/j.ijepes.2024.110034

Zhou, Y. (2024). Resilience analysis and improvement strategy of microgrid system considering new energy connection. PLOS ONE, 19(4), e0301910. https://doi.org/10.1371/journal.pone.0301910

Downloads

Published

13-11-2026

How to Cite

ANALISA KEANDALAN SISTEM CATU DAYA GEDUNG TOWER. (2026). Jurnal Riset Multidisiplin Edukasi, 3(11), 177-206. https://doi.org/10.71282/jurmie.v3i11.2705

Similar Articles

1-10 of 558

You may also start an advanced similarity search for this article.