PENINGKATAN KEPATUHAN PERAWAT DALAM PEMBERSIHAN MICROMIST SETELAH TINDAKAN INHALASI MELALUI PROGRAM SIM-CLEAN (SISTEM MONITORING CLEANING MICROMIST PASCA INHALASI) DI RUANG RAWAT INAP RUMAH SAKIT X DI JAKARTA

Authors

  • Novi Susanti Program Studi Keperawatan Program Sarjana, Sekolah Tinggi Ilmu Kesehatan Sint Carolus, Jakarta, Indonesia Author
  • Ch. Dwiana W Pembimbing Karya Ilmiah Ners, Sekolah Tinggi Ilmu Kesehatan Sint Carolus, Jakarta, Indonesia Author

DOI:

https://doi.org/10.71282/jurmie.v3i9.2549

Keywords:

nurse compliance; micromist; nebulizer; infection prevention and control; HAIs; SIM-CLEAN.

Abstract

Background: Healthcare-Associated Infections (HAIs) are an important indicator of healthcare quality and patient safety. Inhalation therapy devices, including micromist nebulizer components, require appropriate cleaning and handling to minimize contamination and cross-infection risks. A preliminary audit in the 5C Inpatient Ward of Hospital X, Jakarta, showed that nurses’ compliance with micromist cleaning after inhalation therapy was 57.1%, while 42.9% of observed procedures were not compliant with the applicable SOP. Objective: To describe nurses’ baseline compliance and the development of SIM-CLEAN (System for Monitoring Micromist Cleaning After Inhalation) as a nursing management innovation to strengthen compliance with micromist cleaning after inhalation therapy. Methods: A descriptive case report was conducted using direct observation of 56 inhalation procedures over one week, SOP-based compliance auditing, interviews with 10 staff nurses, identification of contributing factors, and development of SIM-CLEAN using the Plan-Do-Check-Act (PDCA) approach. Results: Of 56 observed inhalation procedures, 32 (57.1%) were followed by micromist cleaning according to the SOP, whereas 24 (42.9%) were not. Interview findings identified the absence of a monitoring checklist (90%), visual reminders (80%), cleaning documentation (80%), inadequate supervision (70%), and forgetting to clean the device (60%). Three-month contextual safety data included 3 respiratory infection cases related to care, 2 respiratory-device colonization cases, 1 reported cross-infection event, and 5 near-miss events involving uncleaned inhalation devices. SIM-CLEAN was designed to integrate a monitoring checklist, visual reminders, cleaning documentation, head-nurse supervision, and periodic evaluation. Conclusion: A compliance gap was identified and requires system-level reinforcement. SIM-CLEAN has potential as a nursing management intervention to strengthen monitoring, documentation, supervision, and safety culture. Quantitative effectiveness requires complete post-intervention audit data.

Downloads

Download data is not yet available.

References

Agoramurthi, K., & Berlinski, A. (2024). Effect of disinfection method and testing methodology on the performance of a breath-enhanced jet nebulizer. Pharmaceutics, 16(1), 16. https://doi.org/10.3390/pharmaceutics16010016

Apriana, R., & Tahidji, V. W. (2021). Kepatuhan perawat dalam melaksanakan prosedur hand hygiene perawat di rumah sakit di Gorontalo. Journal Nursing Care, 7(2), 57–64.

Gould, D. J., Moralejo, D., Drey, N., Chudleigh, J. H., & Taljaard, M. (2017). Interventions to improve hand hygiene compliance in patient care. Cochrane Database of Systematic Reviews, 9(9), CD005186. https://doi.org/10.1002/14651858.CD005186.pub4

Ivers, N., Jamtvedt, G., Flottorp, S., Young, J. M., Odgaard-Jensen, J., French, S. D., O'Brien, M. A., Johansen, M., Grimshaw, J., & Oxman, A. D. (2012). Audit and feedback: Effects on professional practice and healthcare outcomes. Cochrane Database of Systematic Reviews, 6, CD000259. https://doi.org/10.1002/14651858.CD000259.pub3

Kementerian Kesehatan Republik Indonesia. (2023). Pedoman pencegahan dan pengendalian infeksi di fasilitas pelayanan kesehatan. Jakarta: Kementerian Kesehatan Republik Indonesia.

Lailawidar, L., Sahputra, I., Usman, S., Nurjannah, & Martoenis. (2021). Health workers compliance towards infection prevention and control in Indonesia. International Journal of Nursing Education, 14(1).

Maryana, M., & Anggraini, R. B. (2021). Nurses' individual characteristics associated with five moments handwashing compliance. Jurnal Ners, 16(2), 136–142. https://doi.org/10.20473/jn.v16i2.22399

O'Malley, C. A. (2015). Device cleaning and infection control in aerosol therapy. Respiratory Care, 60(6), 917–927. https://doi.org/10.4187/respcare.03866

Rutala, W. A., & Weber, D. J. (2019). Guideline for disinfection and sterilization in healthcare facilities. Centers for Disease Control and Prevention.

Sahri, M., Zuhro, R., Hutapea, O., & Dwimarisiana, W. (2021). The relationship of organizational factors and compliance level in the application of standard precautions. Journal of Vocational Health Studies, 5(2), 65–72. https://doi.org/10.20473/jvhs.V5.I2.2021.65-72

Squires, J. E., Sullivan, K., Eccles, M. P., Worswick, J., & Grimshaw, J. M. (2014). Are multifaceted interventions more effective than single-component interventions in changing health-care professionals’ behaviours? An overview of systematic reviews. Implementation Science, 9(1), 152. https://doi.org/10.1186/s13012-014-0152-6

Swanson, C. S., Dhand, R., Cao, L., Ferris, J., Elder, C. S., & He, Q. (2022). Microbiome-based source identification of microbial contamination in nebulizers used by inpatients. Journal of Hospital Infection, 122, 157–161. https://doi.org/10.1016/j.jhin.2022.01.008

Swanson, C. S., Dhand, R., Cao, L., Ferris, J., Elder, C. S., & He, Q. (2023). Microbiome-scale analysis of aerosol facemask contamination during nebulization therapy in hospital. Journal of Hospital Infection, 134, 80–88.

Taylor, M. J., McNicholas, C., Nicolay, C., Darzi, A., Bell, D., & Reed, J. E. (2014). Systematic review of the application of the Plan–Do–Study–Act method to improve quality in healthcare. BMJ Quality & Safety, 23(4), 290–298. https://doi.org/10.1136/bmjqs-2013-001862

World Health Organization. (2022). Infection prevention and control. Geneva: World Health Organization.

World Health Organization. (2022). Report on the burden of endemic health care-associated infection worldwide. World Health Organization.

Downloads

Published

01-09-2026

How to Cite

PENINGKATAN KEPATUHAN PERAWAT DALAM PEMBERSIHAN MICROMIST SETELAH TINDAKAN INHALASI MELALUI PROGRAM SIM-CLEAN (SISTEM MONITORING CLEANING MICROMIST PASCA INHALASI) DI RUANG RAWAT INAP RUMAH SAKIT X DI JAKARTA. (2026). Jurnal Riset Multidisiplin Edukasi, 3(9), 1-10. https://doi.org/10.71282/jurmie.v3i9.2549

Similar Articles

151-160 of 228